UL 790 / ASTM E108

Standard Test Methods for Fire Tests of Roof Coverings

How a roof covering performs against a fire coming from outside the building — a wildfire ember, a neighbour's house, a chimney spark.

What does the test involve?

The two documents use the same test methods. The assembly is evaluated for flame penetration through the covering and deck into the attic, flame spread across the surface, and whether it throws burning brands.

ClassFire test exposureAlso required
Class ASevereDoes not slip from position; unlikely to produce flying brands
Class BModerateDoes not slip from position; unlikely to produce flying brands
Class CLightDoes not slip from position; unlikely to produce flying brands

Common misconceptions

  • The class belongs to the assembly, not the shingle. A Class A shingle over the wrong deck or the wrong underlayment is not a Class A roof.
  • Untreated wood shakes do not carry a class rating. Reaching one requires pressure-impregnated fire-retardant treatment.
  • Class A is the best, not the worst. The lettering runs opposite to school grading intuition for some readers, but A is severe-exposure protection.